Fit and healthy young female for lap. gyne operation, which of the following doesn&;t require continuous monitoring
Correct Answer: ECG
Description: Must be monitored continuously 1. Ventilation : continuously by direct and indirect means : capnography 2. Oxygenation : oximeter 3. Intermittent non-invasive blood pressure monitor 4. Oxygen analyiser with audible alarm to warm of low oxygen concentrations 5. Breathing system disconnection or ventilator failure alarm 6. Volatile anaesthetic agent concentration monitor if using volatile Must be available 1. Electrocardiogram 2. Continuous intra-aerial blood pressure monitor 3. Temperature probe 4. NMB monitoring 5. BIS 6. CVP 7. spirometry 8. TOE