Find out chronaxie and rheobase from the graph given below
Correct Answer: Chronaxie 0.2 msec; rheobas 0.3V
Description: Rheobase is the minimum stimulus strength that will produce a response. It corresponds to 0.3V Chronaxie is the minimum time duration for which a stimulus doubles the rheobase. Double the rheobase is 0.6V which corresponds to 0.2 msec.