In a woman using an intrauterine contraceptive device (IUCD) an intrauterine pregnancy occurs and the IUCD threads are visible. What is the reason to recommend removal of the device?
Correct Answer: To prevent the risk of subsequent septic aboion and preterm labor
Description: - There is no teratogenic risk with a retained IUCD. - However, there may be an increased risk of infection and preterm labour. - Hence, it is recommend to remove the device.